Towers | 2 |
Floors | 19 |
Units | 150 |
Open Area | 30 % |
STRUCTURE
Deep pile foundation complying with seismic 3 zone
RCC frame structure with brickwork and or concrete block partitions
FLOORING AND TILING
Lift lobby and fascia wall and floor using composite marble/vitrified tiles, as per the architects design
Staircases using vitrified tile flooring with hand railing using paint finished MS
Car park Area: Grano flooring with grooves or exterior grade paving tiles
Foyer/Living/Dining/Bed Rooms/Kitchen using 60cm x 60cm vitrified tiles
Toilets: Ceramic tile concepts 30cm x 30cm for floor and 30cm x 45cm for walls up to height of 8 ft (master toilet)
Servants toilet: Ceramic tile 30cm x 30cm for floor and 30cm x 45cm for walls upto 8 ft height
Utility room: 30cm x 30cm for floor and 30cm x 45cm for walls upto 4 ft 6 inch height and 2 ft above the counter if any
Balconies/open terraces/decks: Rustic/antiskid/ceramic tiles 30cm x 30cm or MS railings
SANITARY AND PLUMBING
Sanitary fittings: EWC wall-hung, concealed cisterns Gebrit/Grohe make, counter washbasin and all sanitary fittings shall be of Roca/American Standard or equivalent
Master bed room faucets: Shall be single lever concealed diverters CP finish, heavy body metal fittings of Grohe/Roca or equivalent make
Provision for hot water connection shall be provided for overhead shower in each bathroom
Health faucet also shall be provided
Other toilets: Shall be 3 in 1 mixer CP finish, Over head shower, health faucet by Jaquar or equivalent
Plumbing: All water supply lines shall be in ISI marked CPVC pipes
Drainage lines and storm water drain pipes shall be in PVC
Kitchen and service area: Wall mounted Faucets/taps using Jaguar or equivalent
Stainless steel sink single bowl with drain board of make Nirali or equivalent shall be provided for the kitchen and stainless steel sink without drain board shall be provided for the utility and service areas
Towel rods, towel ring, soap dish and health faucets shall be provided inside the toilets
DOORS AND WINDOWS
Window shutters: Prefabricated colour anodised aluminum/UPVC
Door frames: Main door frame and shutter shall be of seasoned teak wood
Outer face to be PU coated and Inner face melamine finished
Door shutters: All internal door frames shall be of seasoned wood/hard wood with flush door shutter
All internal and external faces shall be melamine finish
Hardware: All hardware shall be in C.P Brass, tower bolts, doorstoppers, ball bearing hinges
Locks shall be mortise of Dorset/Yale make or equivalent
ELECTRICALS
Concealed copper wiring using Finolex or equivalent make with modular plate switches, centralized cabling system for all electrical and communication requirements
Wiring shall be done for lighting, 5Amps, 15 Amps and AC points in the apartment
Switches: All switches shall be Legrand/Schneider or equivalent make
Generator: Power backup will be provided for all common services and selected light and fan point in each living, bedrooms inside apartment and a refrigerator point except air-conditioning and geyser points
Light fixtures for the common areas, external areas, apartment balconies and at entrance door of the individual apartments shall be provided
Adequate ELCB and MCB shall be provided in each apartments
Provision for the geyser points and fresh air fans shall be provided for all toilets
Provision for telephone and Internet shall be provided in the living room and master bed room
CEILING TREATMENT
OBD paint shall be applied in the common areas, utility, service areas
Emulsion paint shall be applied for the ceiling in apartments excluding utility and services
WALL TREATMENT
Internal walls: Acrylic/cement based Putty with emulsion paint
Service area: Oil bound/acrylic distemper
External walls: Whether shield exterior grade emulsion/texture paint
ELEVATORS
Elevators: High Speed lift shall be provided as per the Govt. norms in each core with automatic doors and SS brush finish of Kone or reputed make
AIR CONDITIONING
Provision for split ACs, shall be provided for the master bedroom
Home automation
HOME AUTOMATION
Access control entry to the common entrance/foyers and gymnasium
Home security monitoring, gas leakage detectors, emergency panic intrusion alarm, visitor tracking
Multi level security system for common areas and lobbies